LC1D12V7 | SCHNEIDER ELECTRIC Contactor

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 400 V AC coil

By SCHNEIDER ELECTRIC

References:

SCHNEIDER ELECTRIC : LC1D12V7

SKU : kh011X117_BFR

Condition:

Like new

17.55€ Tax Excl.


Sold by kheoos

17.55€ Tax Excl.

Like new

Advised price

19.59€ Tax Excl. (-10% )


Quantity

For this product, you can only order a maximum of items equal to 2

Availability : In-stock

2 articles remaining in stock


To get a quote, add your products to the basket and generate your quote.

We're shipping in less than 48h

1 offer found for this product

New No offer arrow down
Like new Starting at 17.55€ Tax Excl. arrow down
Refurbished No offer arrow down
Used No offer arrow down
boxes in warehouse

All parts are in stock

With our partners

calculator and quote sheet

Quote

To get a quote, in your basket, click on « get a quote » and add the reference(s)

secure online card payment

Online payment or after quote

If you can not pay by card or bank transfer

receipt

Receive bills

For all your orders

shipping worldwide

Shipping worldwide

warranty certificate

Product warranty

boxes

90 days return

If parts have problems


Specifications

Technical sheet

Download

Other information

Fuse rating to be associated

[en] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance,[fr] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance,[de] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance,[es] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance,[cs] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance,[hu] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance,[sk] 10 A gG pour circuit de signalisation se conformer à IEC 60947-5-140 A gG à <= 690 V coordination type 1 pour circuit de puissance25 A gG à <= 690 V coordination type 2 pour circuit de puissance

Width

45 mm

Connection mode

[en] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble,[fr] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble,[de] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble,[es] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble,[cs] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble,[hu] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble,[sk] Circuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleCircuit de puissance: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleCircuit de puissance: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigide sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigide sans extrémité de câble

Fire resistance

[en] 850 °C se conformer à CEI 60695-2-1,[fr] 850 °C se conformer à CEI 60695-2-1,[de] 850 °C se conformer à CEI 60695-2-1,[es] 850 °C se conformer à CEI 60695-2-1,[cs] 850 °C se conformer à CEI 60695-2-1,[hu] 850 °C se conformer à CEI 60695-2-1,[sk] 850 °C se conformer à CEI 60695-2-1

Height

77 mm

Depth

86 mm

Average impedance

[en] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance,[fr] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance,[de] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance,[es] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance,[cs] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance,[hu] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance,[sk] 2,5 mOhm - Ith 25 A 50 Hz pour circuit de puissance

[icw] rated short-time withstand current

[en] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation,[fr] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation,[de] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation,[es] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation,[cs] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation,[hu] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation,[sk] 105 A à <40 °C - 10 s pour circuit de puissance210 A à <40 °C - 1 s pour circuit de puissance30 A à <40 °C - 10 min pour circuit de puissance61 A à <40 °C - 1 min pour circuit de puissance100 A - 1 s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation

Operating temperature

[en] 5…60 °C,[fr] 5…60 °C,[de] 5…60 °C,[es] 5…60 °C,[cs] 5…60 °C,[hu] 5…60 °C,[sk] 5…60 °C

Ambient temperature for storage

[en] 60…80 °C,[fr] 60…80 °C,[de] 60…80 °C,[es] 60…80 °C,[cs] 60…80 °C,[hu] 60…80 °C,[sk] 60…80 °C

Power loss per pole

[en] 0,36 W AC-31,56 W AC-1,[fr] 0,36 W AC-31,56 W AC-1,[de] 0,36 W AC-31,56 W AC-1,[es] 0,36 W AC-31,56 W AC-1,[cs] 0,36 W AC-31,56 W AC-1,[hu] 0,36 W AC-31,56 W AC-1,[sk] 0,36 W AC-31,56 W AC-1

[ie] rated operational current

[en] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance,[fr] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance,[de] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance,[es] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance,[cs] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance,[hu] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance,[sk] 25 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance12 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance

Nominal switching capacity irms

[en] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1,[fr] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1,[de] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1,[es] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1,[cs] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1,[hu] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1,[sk] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947140 A CA pour circuit de signalisation se conformer à IEC 60947-5-1250 A CC pour circuit de signalisation se conformer à IEC 60947-5-1

[uimp] rated impulse withstand voltage

[en] 6 kV se conformer à IEC 60947,[fr] 6 kV se conformer à IEC 60947,[de] 6 kV se conformer à IEC 60947,[es] 6 kV se conformer à IEC 60947,[cs] 6 kV se conformer à IEC 60947,[hu] 6 kV se conformer à IEC 60947,[sk] 6 kV se conformer à IEC 60947

Operating time

[en] 12…22 ms fermeture4…19 ms ouverture,[fr] 12…22 ms fermeture4…19 ms ouverture,[de] 12…22 ms fermeture4…19 ms ouverture,[es] 12…22 ms fermeture4…19 ms ouverture,[cs] 12…22 ms fermeture4…19 ms ouverture,[hu] 12…22 ms fermeture4…19 ms ouverture,[sk] 12…22 ms fermeture4…19 ms ouverture

Thermal dissipation

[en] 2…3 W à 50/60 Hz,[fr] 2…3 W à 50/60 Hz,[de] 2…3 W à 50/60 Hz,[es] 2…3 W à 50/60 Hz,[cs] 2…3 W à 50/60 Hz,[hu] 2…3 W à 50/60 Hz,[sk] 2…3 W à 50/60 Hz

Hp (ul / csa) engine power

[en] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors,[fr] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors,[de] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors,[es] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors,[cs] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors,[hu] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors,[sk] 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors2 hp at 230/240 V AC 50/60 Hz for 1 phase motors3 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 230/240 V AC 50/60 Hz for 3 phases motors7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors10 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Mechanical endurance

[en] 15 Mcycles,[fr] 15 Mcycles,[de] 15 Mcycles,[es] 15 Mcycles,[cs] 15 Mcycles,[hu] 15 Mcycles,[sk] 15 Mcycles

Control circuit voltage

[en] 400 V CA 50/60 Hz,[fr] 400 V CA 50/60 Hz,[de] 400 V CA 50/60 Hz,[es] 400 V CA 50/60 Hz,[cs] 400 V CA 50/60 Hz,[hu] 400 V CA 50/60 Hz,[sk] 400 V CA 50/60 Hz

[ue] rated operational voltage

[en] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC,[fr] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC,[de] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC,[es] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC,[cs] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC,[hu] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC,[sk] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC

Maximum command speed

[en] 3600 cyc/h à <60 °C,[fr] 3600 cyc/h à <60 °C,[de] 3600 cyc/h à <60 °C,[es] 3600 cyc/h à <60 °C,[cs] 3600 cyc/h à <60 °C,[hu] 3600 cyc/h à <60 °C,[sk] 3600 cyc/h à <60 °C

Rated breaking capacity

[en] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947,[fr] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947,[de] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947,[es] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947,[cs] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947,[hu] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947,[sk] 250 A à 440 V pour circuit de puissance se conformer à IEC 60947

Number of poles

[en] 3P,[fr] 3P,[de] 3P,[es] 3P,[cs] 3P,[hu] 3P,[sk] 3P

Coil technology

[en] Sans module d'antiparasitage intégré,[fr] Sans module d'antiparasitage intégré,[de] Sans module d'antiparasitage intégré,[es] Sans module d'antiparasitage intégré,[cs] Sans module d'antiparasitage intégré,[hu] Sans module d'antiparasitage intégré,[sk] Sans module d'antiparasitage intégré

Minimum switching current

[en] 5 mA pour circuit de signalisation,[fr] 5 mA pour circuit de signalisation,[de] 5 mA pour circuit de signalisation,[es] 5 mA pour circuit de signalisation,[cs] 5 mA pour circuit de signalisation,[hu] 5 mA pour circuit de signalisation,[sk] 5 mA pour circuit de signalisation

Composition of the power pole contacts

[en] 3 NO,[fr] 3 NO,[de] 3 NO,[es] 3 NO,[cs] 3 NO,[hu] 3 NO,[sk] 3 NO

Electrical life

[en] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V,[fr] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V,[de] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V,[es] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V,[cs] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V,[hu] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V,[sk] 2 Mcycles 12 A AC-3 à Ue <= 440 V0,8 Mcycles 25 A AC-1 à Ue <= 440 V

Engine power (kw)

[en] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4),[fr] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4),[de] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4),[es] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4),[cs] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4),[hu] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4),[sk] 3 kW à 220...230 V CA 50/60 Hz (AC-3)5,5 kW à 380...400 V CA 50/60 Hz (AC-3)5,5 kW à 415...440 V CA 50/60 Hz (AC-3)7,5 kW à 500 V CA 50/60 Hz (AC-3)7,5 kW à 660...690 V CA 50/60 Hz (AC-3)3,7 kW à 400 V CA 50/60 Hz (AC-4)

Control circuit voltage range

[en] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C),[fr] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C),[de] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C),[es] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C),[cs] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C),[hu] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C),[sk] Perte de niveau: 0,3 à 0,6 Uc CA 50/60 Hz (à 60 °C)Opérationnel: 0,8 à 1,1 Uc CA 50 Hz (à 60 °C)Opérationnel: 0,85…1,1 Uc CA 60 Hz (à 60 °C)

[ith] conventional thermal current

[en] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation,[fr] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation,[de] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation,[es] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation,[cs] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation,[hu] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation,[sk] 25 A à <60 °C pour circuit de puissance10 A à <60 °C pour circuit de signalisation

[ui] rated insulation voltage

[en] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié,[fr] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié,[de] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié,[es] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié,[cs] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié,[hu] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié,[sk] Circuit de puissance: 690 V se conformer à IEC 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à IEC 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié

Tightening torque

[en] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2,[fr] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2,[de] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2,[es] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2,[cs] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2,[hu] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2,[sk] Circuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmCircuit de puissance: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis empreinte Philips n°2

Engine power

[en] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases,[fr] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases,[de] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases,[es] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases,[cs] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases,[hu] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases,[sk] 4…6 kW at 380…440 V 3 phases4…6 kW at 480…500 V 3 phases2.2…3 kW at 200…240 V 3 phases

Inrush power expressed in va

[en] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C),[fr] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C),[de] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C),[es] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C),[cs] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C),[hu] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C),[sk] 70 VA 60 Hz cos phi 0,75 (à 20 °C)70 VA 50 Hz cos phi 0,75 (à 20 °C)

Average consumption of holding power expressed in va

[en] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C),[fr] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C),[de] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C),[es] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C),[cs] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C),[hu] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C),[sk] 7,5 VA 60 Hz cos phi 0,3 (à 20 °C)7 VA 50 Hz cos phi 0,3 (à 20 °C)

Family

[en] TeSys,[fr] TeSys,[de] TeSys,[es] TeSys,[cs] TeSys,[hu] TeSys,[sk] TeSys

Product origin

Stock origin

European manufacturer of the automotive sector (dormant stock & surplus)

Storage condition

Excellent - Warehouse-ventilated area, away from dust (storage cabinets)

Warranty

3 months

Our other offers

Condition: Vendor Price

Our conditions

Condition: Description
New New - Item never used, unopened, sold in the original packaging
Like New Like New - Item in excellent condition, without signs of wear, in its original packaging or refurbished, small defects possible that do not affect the operation
Refurbished Refurbished - Item repaired, inspected and cleaned by the seller or by a third party not necessarily approved by the manufacturer and in excellent working condition
Used Used - Item having been used, showing some superficial signs of wear, fully operational and working properly

Other products for SCHNEIDER ELECTRIC

Other products for Contactors