BLACK FRIDAY WEEK

30% Off on all kheoos market offers and up to 60% discount on selected references

Contact us Monday to Friday from 8:30am to 5:00pm

Language

Delivery country

Currency

Do not have an account yet?

Basket

Your basket is empty

What's new

white helmet

Customer voice

house, lamp and solar panel

News at kheoos

LC2D40AFE7 | SCHNEIDER ELECTRIC Reversing contactor

TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 115 V AC coil

By SCHNEIDER ELECTRIC

References:

SCHNEIDER ELECTRIC : LC2D40AFE7

SKU : kh016I878_BFR

Condition:

Like new

260.72€ Tax Excl.


Sold by kheoos

260.72€ Tax Excl.

Like new


Quantity

For this product, you can only order a maximum of items equal to 3

Availability : In-stock

3 articles remaining in stock


To get a quote, add your products to the basket and generate your quote.

We're shipping in less than 48h

1 offer found for this product

New No offer arrow down
Like new Starting at 260.72€ Tax Excl. arrow down
Refurbished No offer arrow down
Used No offer arrow down
boxes in warehouse

All parts are in stock

With our partners

calculator and quote sheet

Quote

To get a quote, in your basket, click on « get a quote » and add the reference(s)

secure online card payment

Online payment or after quote

If you can not pay by card or bank transfer

receipt

Receive bills

For all your orders

shipping worldwide

Shipping worldwide

warranty certificate

Product warranty

boxes

90 days return

If parts have problems


Specifications

Technical sheet

Download

Other information

Width

119 mm

Fuse rating to be associated

[fr] 10 A gG pour circuit de signalisation se conformer à CEI 60947-5-180 A gG à <= 690 V coordination type 1 pour circuit de puissance80 A gG à <= 690 V coordination type 2 pour circuit de puissance

Connection mode

[fr] Télécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²souple sans extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 2 câble(s) 1…2,5 mm²souple avec extrémité de câbleTélécommande: borniers à vis-étrier 1 câble(s) 1…4 mm²rigideTélécommande: borniers à vis-étrier 2 câble(s) 1…4 mm²rigideCircuit de puissance: connecteurs à vis BTR EverLink 1 câble(s) 1…35 mm²souple sans extrémité de câbleCircuit de puissance: connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm²souple sans extrémité de câbleCircuit de puissance: connecteurs à vis BTR EverLink 1 câble(s) 1…35 mm²souple avec extrémité de câbleCircuit de puissance: connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm²souple avec extrémité de câbleCircuit de puissance: connecteurs à vis BTR EverLink 1 câble(s) 1…35 mm²rigideCircuit de puissance: connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm²rigide

Fire resistance

[fr] 850 °C se conformer à CEI 60695-2-1

Length

19.50 cm

Height

122 mm

Depth

120 mm

Average impedance

[fr] 1,5 mOhm - Ith 60 A 50 Hz pour circuit de puissance

[icw] rated short-time withstand current

[fr] 72 A à <40 °C - 10 min pour circuit de puissance165 A à <40 °C - 1 min pour circuit de puissance320 A à <40 °C - 10 s pour circuit de puissance720 A à <40 °C - 1s pour circuit de puissance100 A - 1s pour circuit de signalisation120 A - 500 ms pour circuit de signalisation140 A - 100 ms pour circuit de signalisation

Operating temperature

[fr] 40…60 °C60…70 °C avec réduction de courant

Power loss per pole

[fr] 2,4 W AC-35,4 W AC-1

[ie] rated operational current

[fr] 40 A (à <60 °C) à <= 440 V CA AC-3 pour circuit de puissance60 A (à <60 °C) à <= 440 V CA AC-1 pour circuit de puissance

Nominal switching capacity irms

[fr] 140 A CA pour circuit de signalisation se conformer à CEI 60947-5-1250 A CC pour circuit de signalisation se conformer à CEI 60947-5-1800 A à 440 V pour circuit de puissance se conformer à CEI 60947

[uimp] rated impulse withstand voltage

[fr] 6 kV se conformer à CEI 60947

Operating time

[fr] 4…19 ms ouverture12…26 ms fermeture

Thermal dissipation

[fr] 4…5 W à 50/60 Hz

Hp (ul / csa) engine power

[en] 5 hp at 230/240 V AC 60 Hz for 1 phase motors10 hp at 230/240 V AC 60 Hz for 3 phases motors30 hp at 575/600 V AC 60 Hz for 3 phases motors10 hp at 200/208 V AC 60 Hz for 3 phases motors3 hp at 115 V AC 60 Hz for 1 phase motors30 hp at 460/480 V AC 60 Hz for 3 phases motors,[hu] 5 LE -230/240 V AC 60 Hz esetén kétfázisú motorok10 LE -230/240 V AC 60 Hz esetén 3 fázis motorok30 LE -575/600 V AC 60 Hz esetén 3 fázis motorok10 LE -200/208 V AC 60 Hz esetén 3 fázis motorok3 LE -115 Veff AC 60 Hz esetén kétfázisú motorok30 LE -460/480 V AC 60 Hz esetén 3 fázis motorok,[sk] 5 hp při 230/240 V AC 60 Hz pro 1 fáz. motory10 hp při 230/240 V AC 60 Hz pro 3 fáz. motory30 hp při 575/600 V AC 60 Hz pro 3 fáz. motory10 hp při 200/208 V AC 60 Hz pro 3 fáz. motory3 hp při 115 V AC 60 Hz pro 1 fáz. motory30 hp při 460/480 V AC 60 Hz pro 3 fáz. motory

Mechanical endurance

[fr] 6 Mcycles

[ue] rated operational voltage

[fr] Circuit de puissance: <= 690 V CA 25...400 HzCircuit de puissance: <= 300 V CC

Maximum command speed

[fr] 3600 cyc/h à <60 °C

Rated breaking capacity

[fr] 800 A à 440 V pour circuit de puissance se conformer à CEI 60947

Number of poles

[fr] 3P

Coil technology

[fr] Sans module d'antiparasitage intégré

Minimum switching current

[fr] 5 mA pour circuit de signalisation

Electrical life

[fr] 1,5 Mcycles 40 A AC-3 à Ue <= 440 V1,4 Mcycles 60 A AC-1 à Ue <= 440 V

Composition of the power pole contacts

[en] 3 NO,[hu] 3 NO,[sk] 3 NO

Engine power (kw)

[fr] 18,5 kW à 380...400 V CA 50 Hz11 kW à 220...230 V CA 50 Hz22 kW à 415...440 V CA 50 Hz22 kW à 500 V CA 50 Hz30 kW à 660...690 V CA 50 Hz

Control circuit voltage range

[fr] 0,3 à 0,6 Uc -40…70 °C perte de niveau CA 50/60 Hz0,8 à 1,1 Uc -40…60 °C opérationnel CA 50 Hz0,85…1,1 Uc -40…60 °C opérationnel CA 60 Hz1...1,1 Uc 60…70 °C opérationnel CA 50/60 Hz

[ith] conventional thermal current

[fr] 10 A à <60 °C pour circuit de signalisation60 A à <60 °C pour circuit de puissance

[ui] rated insulation voltage

[fr] Circuit de puissance: 690 V se conformer à CEI 60947-4-1Circuit de puissance: 600 V CSA certifiéCircuit de puissance: 600 V UL certifiéCircuit de signalisation: 690 V se conformer à CEI 60947-1Circuit de signalisation: 600 V CSA certifiéCircuit de signalisation: 600 V UL certifié

Tightening torque

[fr] Télécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis plat Ø 6 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis cruciforme Philips n° 2Circuit de puissance: 8 N.m - sur connecteurs à vis BTR EverLink - câble 25…35 mm² hexagonal 4 mmCircuit de puissance: 5 N.m - sur connecteurs à vis BTR EverLink - câble 1…25 mm² hexagonal 4 mmTélécommande: 1,7 N.m - sur borniers à vis-étrier - avec tournevis pozidriv n°2Circuit de puissance: 2,5 N.m - sur borniers à vis-étrier - avec tournevis pozidriv n°2

Inrush power expressed in va

[fr] 140 VA 60 Hz cos phi 0,75 (à 20 °C)160 VA 50 Hz cos phi 0,75 (à 20 °C)

Average consumption of holding power expressed in va

[fr] 13 VA 60 Hz cos phi 0,3 (à 20 °C)15 VA 50 Hz cos phi 0,3 (à 20 °C)

Product origin

Stock origin

European Industrialist in the energy sector (dormant stock & surplus)

Storage condition

Excellent - Warehouse-ventilated area, away from dust (storage cabinets)

Warranty

3 months

Our other offers

Condition: Vendor Price

Our conditions

Condition: Description
New New - Item never used, unopened, sold in the original packaging
Like New Like New - Item in excellent condition, without signs of wear, in its original packaging or refurbished, small defects possible that do not affect the operation
Refurbished Refurbished - Item repaired, inspected and cleaned by the seller or by a third party not necessarily approved by the manufacturer and in excellent working condition
Used Used - Item having been used, showing some superficial signs of wear, fully operational and working properly

Other products for SCHNEIDER ELECTRIC

Other products for Contactors