LP2K0901BD3 | SCHNEIDER ELECTRIC TeSys K

reversing Contactor, TeSys K, 3P, AC-3/AC-3e,440V 9A, 1NC, 24V DC coil,with integral suppression device

By SCHNEIDER ELECTRIC

References:

SCHNEIDER ELECTRIC : LP2K0901BD3

SKU : kh015N638_BFR

Condition:

Like new

43.16€ Tax Excl.


Sold by kheoos

43.16€ Tax Excl.

Like new


Quantity

For this product, you can only order a maximum of items equal to 3

Availability : In-stock

3 articles remaining in stock


To get a quote, add your products to the basket and generate your quote.

We're shipping in less than 48h

1 offer found for this product

New No offer arrow down
Like new Starting at 43.16€ Tax Excl. arrow down
Refurbished No offer arrow down
Used No offer arrow down
boxes in warehouse

All parts are in stock

With our partners

calculator and quote sheet

Quote

To get a quote, in your basket, click on « get a quote » and add the reference(s)

secure online card payment

Online payment or after quote

If you can not pay by card or bank transfer

receipt

Receive bills

For all your orders

shipping worldwide

Shipping worldwide

warranty certificate

Product warranty

boxes

90 days return

If parts have problems


Specifications

Technical sheet

Download

Other information

Fuse rating to be associated

[fr] 25 A gG à <= 440 V pour circuit de puissance25 A aM pour circuit de puissance10 A gG pour circuit de signalisation se conformer à CEI 6094710 A gG pour circuit de signalisation se conformer à VDE 0660

Connection mode

[fr] Borniers à vis-étrier 1 câble(s) 1,5…4 mm²rigideBorniers à vis-étrier 1 câble(s) 0,75…4 mm²souple sans extrémité de câbleBorniers à vis-étrier 1 câble(s) 0,34…2,5 mm²souple avec extrémité de câbleBorniers à vis-étrier 2 câble(s) 1,5…4 mm²rigideBorniers à vis-étrier 2 câble(s) 0,75…4 mm²souple sans extrémité de câbleBorniers à vis-étrier 2 câble(s) 0,34…1,5 mm²souple avec extrémité de câble

Average impedance

[fr] 3 mOhm - Ith 20 A 50 Hz pour circuit de puissance

[icw] rated short-time withstand current

[fr] 90 A à = 15 min pour circuit de puissance

[ie] rated operational current

[fr] 20 A (à <50 °C) à <= 440 V CA AC-1 pour circuit de puissance16 A (à <70 °C) à 690 V CA AC-1 pour circuit de puissance9 A à <= 440 V CA AC-3 pour circuit de puissance9 A à <= 440 V CA AC-3e pour circuit de puissance

Nominal switching capacity irms

[fr] 110 A CA pour circuit de puissance se conformer à NF C 63-110110 A CA pour circuit de puissance se conformer à CEI 60947110 A CA pour circuit de signalisation se conformer à CEI 60947

[uimp] rated impulse withstand voltage

[fr] 8 kV

Operating time

[fr] 30…40 ms excitation bobine + fermeture "F"10 ms désexcitation bobine + ouverture "F"

Thermal dissipation

[fr] 3 W

Mechanical endurance

[fr] 5 Mcycles

Inrush power in w

[fr] 3 W (à 20 °C)

[ue] rated operational voltage

[fr] Circuit de puissance: 690 V CA 50/60 HzCircuit de signalisation: <= 690 V CA 50/60 Hz

Maximum command speed

[fr] 3600 cyc/h

Rated breaking capacity

[fr] 110 A à 415 V se conformer à CEI 60947110 A à 440 V se conformer à CEI 6094780 A à 500 V se conformer à CEI 60947110 A à 220...230 V se conformer à CEI 60947110 A à 380...400 V se conformer à CEI 6094770 A à 660...690 V se conformer à CEI 60947

Number of poles

[fr] 3P

Coil technology

[fr] Suppresseur à diode de limite de crête bidirectionnel incorporé

Minimum switching current

[fr] 5 mA pour circuit de signalisation

Composition of the power pole contacts

[en] 3 NO,[es] 3 NA,[hu] 3 NO,[sk] 3 NO

Electrical life

[fr] 0,18 Mcycles 20 A AC-1 à Ue <= 440 V1,3 Mcycles 9 A AC-3 à Ue <= 440 V1,3 Mcycles 9 A AC-3e à Ue <= 440 V

Engine power (kw)

[fr] 2,2 kW à 220...230 V CA 50/60 Hz4 kW à 380...415 V CA 50/60 Hz4 kW à 440 V CA 50/60 Hz4 kW à 480 V CA 50/60 Hz4 kW à 500 à 600 V CA 50/60 Hz4 kW à 660...690 V CA 50/60 Hz

Control circuit voltage range

[fr] Opérationnel: 0,8…1,15 Uc (à <50 °C)Perte de niveau: 0,1 à 0,75 Uc (à <50 °C)

[ith] conventional thermal current

[fr] 20 A à <50 °C) pour circuit de puissance10 A à <50 °C) pour circuit de signalisation

[ui] rated insulation voltage

[fr] Circuit de puissance: 600 V se conformer à UL 508Circuit de puissance: 690 V se conformer à CEI 60947-4-1Circuit de signalisation: 690 V se conformer à CEI 60947-4-1Circuit de signalisation: 690 V se conformer à CEI 60947-5-1Circuit de signalisation: 600 V se conformer à UL 508Circuit de puissance: 600 V se conformer à CSA C22.2 No 14Circuit de signalisation: 600 V se conformer à CSA C22.2 No 14

Tightening torque

[fr] 0,8…1,3 N.m - sur borniers à vis-étrier cruciforme Philips n° 20,8…1,3 N.m - sur borniers à vis-étrier plat Ø 6 mm0,8…1,3 N.m - sur borniers à vis-étrier pozidriv n°2

Family

[fr] TeSys,[es] TeSys

Product origin

Stock origin

European manufacturer of the automotive sector (dormant stock & surplus)

Storage condition

Good - Storage on pallets in sealed area and ventilated

Warranty

3 months

Our other offers

Condition: Vendor Price

Our conditions

Condition: Description
New New - Item never used, unopened, sold in the original packaging
Like New Like New - Item in excellent condition, without signs of wear, in its original packaging or refurbished, small defects possible that do not affect the operation
Refurbished Refurbished - Item repaired, inspected and cleaned by the seller or by a third party not necessarily approved by the manufacturer and in excellent working condition
Used Used - Item having been used, showing some superficial signs of wear, fully operational and working properly

Other products for SCHNEIDER ELECTRIC

Other products for Contactors