GV3P50 | SCHNEIDER ELECTRIC Thermal magnetic circuit protector

TeSys Deca Manual Starter and Protector, thermal magnetic circuit protector, rotary knob, 37 to 50 A, EverLink BTR

By SCHNEIDER ELECTRIC

References:

SCHNEIDER ELECTRIC : GV3P50

SKU : kh014P264_DFR

Condition:

Refurbished

26.88€ Tax Excl.


Sold by kheoos

26.88€ Tax Excl.

Refurbished


Quantity

For this product, you can only order a maximum of items equal to 1

Availability : In-stock

1 article remaining in stock


To get a quote, add your products to the basket and generate your quote.

We're shipping in less than 48h

1 offer found for this product

New No offer arrow down
Like new No offer arrow down
Refurbished Starting at 26.88€ Tax Excl. arrow down
Used No offer arrow down
boxes in warehouse

All parts are in stock

With our partners

calculator and quote sheet

Quote

To get a quote, in your basket, click on « get a quote » and add the reference(s)

secure online card payment

Online payment or after quote

If you can not pay by card or bank transfer

receipt

Receive bills

For all your orders

shipping worldwide

Shipping worldwide

warranty certificate

Product warranty

boxes

90 days return

If parts have problems


Specifications

Technical sheet

Download

Other information

Connection mode

[en] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble,[fr] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble,[de] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble,[es] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble,[cs] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble,[hu] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble,[sk] Connecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² rigideConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple sans extrémité de câbleConnecteurs à vis BTR EverLink 2 câble(s) 1…25 mm² souple avec extrémité de câble

Fire resistance

[en] 960 °C se conformer à CEI 60695-2-1,[fr] 960 °C se conformer à CEI 60695-2-1,[de] 960 °C se conformer à CEI 60695-2-1,[es] 960 °C se conformer à CEI 60695-2-1,[cs] 960 °C se conformer à CEI 60695-2-1,[hu] 960 °C se conformer à CEI 60695-2-1,[sk] 960 °C se conformer à CEI 60695-2-1

Mechanical endurance

[en] 50000 cycle,[fr] 50000 cycle,[de] 50000 cycle,[es] 50000 cycle,[cs] 50000 cycle,[hu] 50000 cycle,[sk] 50000 cycle

Magnetic tripping current

[en] 700 A,[fr] 700 A,[de] 700 A,[es] 700 A,[cs] 700 A,[hu] 700 A,[sk] 700 A

[ue] rated operational voltage

[en] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[fr] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[de] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[es] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[cs] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[hu] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[sk] 690 V CA 50/60 Hz se conformer à IEC 60947-2

Maximum command speed

[en] 25 cyc/h,[fr] 25 cyc/h,[de] 25 cyc/h,[es] 25 cyc/h,[cs] 25 cyc/h,[hu] 25 cyc/h,[sk] 25 cyc/h

[ics] rated short-circuit service breaking capacity

[en] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2,[fr] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2,[de] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2,[es] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2,[cs] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2,[hu] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2,[sk] 100 % à 230/240 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 440 V CA 50/60 Hz se conformer à IEC 60947-2100 % à 400/415 V CA 50/60 Hz se conformer à IEC 60947-250 % à 500 V CA 50/60 Hz se conformer à IEC 60947-250 % à 690 V CA 50/60 Hz se conformer à IEC 60947-2

Number of poles

[en] 3P,[fr] 3P,[de] 3P,[es] 3P,[cs] 3P,[hu] 3P,[sk] 3P

Operating temperature

[en] 20…60 °C,[fr] 20…60 °C,[de] 20…60 °C,[es] 20…60 °C,[cs] 20…60 °C,[hu] 20…60 °C,[sk] 20…60 °C

Ambient temperature for storage

[en] 40…80 °C,[fr] 40…80 °C,[de] 40…80 °C,[es] 40…80 °C,[cs] 40…80 °C,[hu] 40…80 °C,[sk] 40…80 °C

Command type

[en] Bouton rotatif,[fr] Bouton rotatif,[de] Bouton rotatif,[es] Bouton rotatif,[cs] Bouton rotatif,[hu] Bouton rotatif,[sk] Bouton rotatif

Power loss per pole

[en] 8 W,[fr] 8 W,[de] 8 W,[es] 8 W,[cs] 8 W,[hu] 8 W,[sk] 8 W

Rated usage current

[en] 50 A,[fr] 50 A,[de] 50 A,[es] 50 A,[cs] 50 A,[hu] 50 A,[sk] 50 A

Electrical life

[en] 50000 cycle pour AC-3 à 440 V In,[fr] 50000 cycle pour AC-3 à 440 V In,[de] 50000 cycle pour AC-3 à 440 V In,[es] 50000 cycle pour AC-3 à 440 V In,[cs] 50000 cycle pour AC-3 à 440 V In,[hu] 50000 cycle pour AC-3 à 440 V In,[sk] 50000 cycle pour AC-3 à 440 V In

Engine power (kw)

[en] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz,[fr] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz,[de] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz,[es] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz,[cs] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz,[hu] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz,[sk] 22 kW à 400/415 V CA 50/60 Hz30 kW à 500 V CA 50/60 Hz45 kW à 690 V CA 50/60 Hz

[uimp] rated impulse withstand voltage

[en] 6 kV se conformer à IEC 60947-2,[fr] 6 kV se conformer à IEC 60947-2,[de] 6 kV se conformer à IEC 60947-2,[es] 6 kV se conformer à IEC 60947-2,[cs] 6 kV se conformer à IEC 60947-2,[hu] 6 kV se conformer à IEC 60947-2,[sk] 6 kV se conformer à IEC 60947-2

[ith] conventional thermal current

[en] 50 A se conformer à IEC 60947-4-1,[fr] 50 A se conformer à IEC 60947-4-1,[de] 50 A se conformer à IEC 60947-4-1,[es] 50 A se conformer à IEC 60947-4-1,[cs] 50 A se conformer à IEC 60947-4-1,[hu] 50 A se conformer à IEC 60947-4-1,[sk] 50 A se conformer à IEC 60947-4-1

[ui] rated insulation voltage

[en] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[fr] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[de] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[es] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[cs] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[hu] 690 V CA 50/60 Hz se conformer à IEC 60947-2,[sk] 690 V CA 50/60 Hz se conformer à IEC 60947-2

Tightening torque

[en] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²,[fr] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²,[de] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²,[es] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²,[cs] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²,[hu] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²,[sk] 5 N.m sur connecteurs à vis BTR EverLink pour câble 25 mm²8 N.m sur connecteurs à vis BTR EverLink pour câble 35 mm²

Family

[en] TeSys,[fr] TeSys,[de] TeSys,[es] TeSys,[cs] TeSys,[hu] TeSys,[sk] TeSys

Product origin

Stock origin

European food industry manufacturer (dormant stock & surplus)

Storage condition

Good - Storage on pallets in sealed area and ventilated

Warranty

3 months

Our other offers

Condition: Vendor Price
Refurbished kheoos Voir les produits du vendeur 26.88€ Tax Excl. (par unité)

Our conditions

Condition: Description
New New - Item never used, unopened, sold in the original packaging
Like New Like New - Item in excellent condition, without signs of wear, in its original packaging or refurbished, small defects possible that do not affect the operation
Refurbished Refurbished - Item repaired, inspected and cleaned by the seller or by a third party not necessarily approved by the manufacturer and in excellent working condition
Used Used - Item having been used, showing some superficial signs of wear, fully operational and working properly

Other products for SCHNEIDER ELECTRIC

Other products for Residential RCBOs